Service overview
Magnetic particle inspection reveals surface-breaking and some very shallow near-surface flaws in ferromagnetic materials. A magnetic field is applied, and fine iron particles gather at flaws to make them visible.
Purpose and industrial applications
- Weld toes and weld surfaces on boiler and pressure parts
- Crack checks after grinding or repair
- In-service inspection of accessible surfaces
Components and materials
- Carbon and low-alloy steel welds
- Tube and pipe surfaces
- Nozzles, attachments and supports
Inspection methods and equipment
- Electromagnetic yoke and portable DC yoke
- Permanent magnetic yoke where power is unavailable
- Dry powders or wet magnetic inks, with pie field indicator and UV light where applicable
Typical procedure
- Clean the surface and remove loose scale
- Verify field strength and direction
- Apply the magnetic field and particles in two directions
- Examine under suitable lighting
- Record indications and report
Applicable codes and standards
ASME BPVC Section V (magnetic particle examination) is commonly referenced. The acceptance limits come from the construction or in-service code or the client specification.
The applicable standard depends on the equipment, material, service conditions, statutory requirements and the approved scope of work.
Deliverables and reporting
- Report with indication locations and sketches or photographs
- Technique details such as yoke type and particles used
- Accept or reject findings against the agreed criteria
Scope limitations and site requirements
- Works only on ferromagnetic materials, so it is not suitable for austenitic stainless steel
- Detects surface and very shallow near-surface flaws, not deeper subsurface defects
- Heavy coatings and rough surfaces reduce sensitivity
Frequently asked questions
Can MPI find all subsurface defects?
No. Its sensitivity falls quickly with depth. Deeper flaws need a method such as ultrasonic testing.
Can it be used on stainless steel?
Austenitic stainless steels are generally not magnetic, so dye penetrant testing is used instead.
ISO 9001:2015Certified quality management
On-time complianceESIC, PF and MLWF awards
Safety firstPPE and LOTO kits in use
60+ page reportsDetailed documentation per project
IBR-certified weldersFor boiler pressure parts
Planning a shutdown or facing a breakdown?
We know your urgency. Tell us the problem and we will plan the right testing.