We know your urgency. Call us: +91 98554 45055
Vishwakarma Technical Services (VTS)
Pune, India · RLA & NDT specialists
Home / Equipment

Equipment and Inspection Instruments

Portable inspection, calibration, metallurgical and safety equipment used on our assignments.

Equipment catalogue

21 instruments we use

Where equipment is hired or supplied by the client, this is stated in the job scope.

Crack detection

Electromagnetic Yoke

A handheld articulated magnet that quickly pulls a magnetic field through a part to expose surface-breaking cracks.

Method supported
Magnetic particle inspection
Typical application
Weld surfaces and base metal on boiler and pressure parts.
Limitations and calibration
Needs mains or battery power. Check lifting power and field strength before use, and use only on ferromagnetic material.

Permanent Magnetic Yoke

A cordless, non-electric handheld magnet used for surface crack detection where power outlets are unavailable or unsafe.

Method supported
Magnetic particle inspection
Typical application
Field work in areas without power and in areas where electrical equipment is restricted.
Limitations and calibration
Field strength is fixed and cannot be adjusted. Verify the pull strength regularly.

Portable DC Magnetic Yoke

A battery or rectified power unit that gives deeper magnetic penetration, so it can find defects slightly below the surface.

Method supported
Magnetic particle inspection
Typical application
Welds and thicker sections where deeper magnetisation is useful.
Limitations and calibration
Still limited to surface and very shallow near-surface flaws. Not a method for reliably finding deeper subsurface defects.

Magnetic Ink and Inspection Powders

Finely milled iron particles, in high-contrast dry colours or wet fluorescent form, that gather at a crack and make the flaw visible.

Method supported
Magnetic particle inspection
Typical application
Applied over the magnetised area to reveal indications.
Limitations and calibration
Check the particle concentration and contrast. Ink and powder have a shelf life and should be kept clean.

Pie Field Indicator (Pie Gauge)

A circular tool placed on the surface during testing to verify that the magnetic field is strong enough and pointing in a suitable direction.

Method supported
Magnetic particle inspection
Typical application
Quick check of field presence and direction on the job.
Limitations and calibration
Gives a qualitative indication of field. It does not replace quantitative field measurement where that is required.

Liquid Penetrant Testing Kit

A three-part chemical system of cleaner, penetrant and developer used to draw fine surface cracks out into plain sight.

Method supported
Dye penetrant testing
Typical application
Stainless steel, alloy and non-ferrous parts, and weld surfaces.
Limitations and calibration
Surface must be clean and dry. Consumables have a shelf life and must be used as per the procedure and temperature range.

Torch and UV Inspection Light

An industrial torch or UV light used to light tight inspection areas or to activate fluorescent dyes and powders.

Method supported
Visual, magnetic particle and penetrant testing
Typical application
Lighting for inspection and examination of fluorescent indications.
Limitations and calibration
Light level and UV intensity must suit the method, and ambient white light affects fluorescent work.

Ultrasonic and thickness

Ultrasonic Flaw Detector

A portable digital unit that uses high-frequency sound waves to map internal subsurface cracks, voids and weld defects.

Method supported
Ultrasonic testing
Typical application
Weld examination and internal flaw detection in plates, pipes and pressure parts.
Limitations and calibration
Needs calibration on a reference block before use. Results depend on surface condition and operator skill.

Ultrasonic Probes and Transducers

The sensors, available in normal, angle or phased-array options, that send sound waves into the material and receive the returning echo.

Method supported
Ultrasonic testing
Typical application
Chosen by the thickness, material and type of flaw to be found.
Limitations and calibration
Probes wear and must be checked. The probe type and frequency must suit the job and be recorded.

V2 Calibration Block

A small standardised steel block used in the field to calibrate the time base, gain and beam exit angle of ultrasonic probes.

Method supported
Ultrasonic testing
Typical application
Instrument and probe calibration before and during ultrasonic work.
Limitations and calibration
Only valid for the calibration tasks it is designed for. Keep the block clean and undamaged.
12.7

Step Gauge

A tiered metal block with steps of known thickness, used to quickly calibrate thickness gauges before starting a scan.

Method supported
Ultrasonic thickness measurement
Typical application
Calibration of thickness gauges at the start of a job.
Limitations and calibration
The block material should be similar to the material being measured, and the gauge must be rechecked during long jobs.
12.7

Ultrasonic Thickness Gauge

A compact handheld meter built to measure remaining wall thickness and identify hidden internal corrosion in pipes, tubes and tanks.

Method supported
Ultrasonic thickness measurement
Typical application
Wall-loss surveys of boiler tubes, vessels and pipes.
Limitations and calibration
Surface condition, scale and temperature affect accuracy. Calibrate before use and use suitable probes for hot surfaces.
12.7

Oxide Scale Measurement Instrument

A specialised ultrasonic tool that measures internal oxide scale build-up in boiler tubes.

Method supported
Ultrasonic oxide scale measurement
Typical application
Assessment of high-temperature boiler tubes as part of RLA.
Limitations and calibration
Not suitable for every scale condition or tube geometry, and some cases still need other methods. Results are an estimate and are used with other data.

Metallurgy and hardness

MAGNETIC BASE

In-situ Metallography Kit

A portable polishing and replication kit used to examine the microscopic grain structure of a metal component directly on the job site.

Method supported
In-situ metallography and replication
Typical application
Microstructure examination on boiler tubes, headers and pipes.
Limitations and calibration
Quality depends on surface preparation, and the structure is seen only at the locations examined. Interpretation needs a qualified metallurgist.
MAGNETIC BASE

Portable Metallurgical Microscope

A compact field microscope with a digital camera, used to inspect surfaces and plastic replicas on site for early-stage creep cavitation and grain boundary cracking.

Method supported
In-situ metallography and replication
Typical application
Examination and recording of microstructures on site.
Limitations and calibration
Image quality depends on preparation and lighting. Keep optics clean and protected.
HLD

Portable Hardness Tester

A portable impact or indentation tool used to check the hardness level of a metal component directly in the field.

Method supported
Hardness testing
Typical application
Weld, heat-affected zone and base metal hardness checks.
Limitations and calibration
Surface finish and thin sections affect results, and scale conversions are approximate. Verify the tester on a test block.

Visual and dimensional

Borescope

A flexible or rigid tube camera fed into internal pipes, tubes or cavities to visually check for internal damage.

Method supported
Borescope and visual inspection
Typical application
Internal checks of pipes, tubes and headers where access allows.
Limitations and calibration
Shows visual condition only, and dirt or liquid limits the view. It does not measure wall thickness.
12.7

Welding and Pitting Gauge

A mechanical pocket tool used to measure weld bead height, fillet size, root alignment and the depth of surface corrosion pits.

Method supported
Visual inspection
Typical application
Weld profile and pit depth checks during inspection.
Limitations and calibration
Mechanical gauges must be checked for wear and used on a clean surface.
12.7

Vernier Caliper

A high-precision manual or digital slide tool used to measure exact outer diameters, inner gaps and depths of mechanical parts.

Method supported
Dimensional inspection
Typical application
Measuring tube diameters, gaps and part dimensions.
Limitations and calibration
Needs a clean, undamaged measuring face and periodic calibration against a standard.

Safety

Safety Harness Belt

A fall-arrest body harness required for inspectors working at height, on scaffolding or inside tall storage vessels.

Method supported
Personal safety equipment
Typical application
Work at height and in confined or elevated areas.
Limitations and calibration
Inspect before each use, replace after any fall and follow the manufacturer's service life and site rules.

Safety Helmet

An impact-resistant hard hat that protects technicians from falling debris on industrial sites and construction areas.

Method supported
Personal safety equipment
Typical application
Mandatory personal protection on industrial sites.
Limitations and calibration
Replace if cracked or after a heavy impact, and follow the manufacturer's service life.
ISO 9001:2015Certified quality management
On-time complianceESIC, PF and MLWF awards
Safety firstPPE and LOTO kits in use
60+ page reportsDetailed documentation per project
IBR-certified weldersFor boiler pressure parts

Planning a shutdown or facing a breakdown?

We know your urgency. Tell us the problem and we will plan the right testing.

Send an enquiry
Send enquiry