We know your urgency. Call us: +91 98554 45055
Vishwakarma Technical Services (VTS)
Pune, India · RLA & NDT specialists
Vishwakarma Technical Services · Pune, India · Projects across the Middle East, Asia and Africa

Boiler Inspection, Maintenance and RLA, with Advanced NDT Services

Engineering inspection, in-situ metallography, material condition assessment, and industrial repair support for boilers, heaters, superheaters, economisers, air pre-heaters, pressure vessels, and critical plant equipment.

1300+Projects served
1000+Companies served across sectors
10+ yearsIn business, from Pune
5+ countriesServed over our journey
We know your urgency

From your call to our team on site in 24–48 hours

Shutdowns do not wait. This is the path every VTS job follows.

24–48 h Enquiry loggedEngineering reviewTeam & kits mobilisedOn site, testingReport & advice hour 0same day24–48 hon schedule60+ pages
Why VTS

Why industry chooses VTS

A Pune-based specialist in RLA, NDT / NDE, third-party inspection, ISO audits and boiler repair, working directly with manufacturers and plant owners.

ISO 9001:2015 certified

A certified quality management system stands behind our inspection, audit and repair work.

Detailed 60+ page reports

Each project is documented in a comprehensive technical report of 60+ pages: inspection data, findings, analysis and recommendations.

On-time statutory compliance

Awarded for on-time compliance with ESIC, PF, MLWF and other statutory requirements.

20+ years of experience

Certified technicians with more than 20 years of field experience.

Line quality, lowest DPU

Third-party line inspection to achieve and maintain quality with the lowest defects per unit (DPU), including in the automotive sector.

International projects

Dubai, Qatar, Malaysia, Thailand, African countries, the Philippines, Singapore and more, with technicians ready for overseas work.

About Us

Global reach

Projects from Pune to the world

Our technicians are ready for overseas work, with passports, visas and vaccinations in place.

Middle EastDubai, Qatar AfricaAfrican countries Southeast AsiaMalaysia, Thailand,Philippines, Singapore And moreProjects across sectors PuneIndia base

Pune, India

Our base

Middle East

Dubai, Qatar

Southeast Asia

Malaysia, Thailand, Philippines, Singapore

Africa

African countries

And more

Projects across sectors

Our priority

Safety first, on every job

Safety comes before schedule. Our technicians are always aware of factory safety induction requirements and are trained in the safe use of machines and equipment.

Safety induction

Factory safety induction before work begins.

Safe machine use

Safe operation of machines, tools and instruments.

PPE worn

Required PPE worn throughout the work.

LOTO kits

Lockout / tagout kits isolate and secure energy sources before work begins.

How RLA works

Our RLA process in six steps

Data review

Design data, operating history and past records.

Surface checks

Visual, magnetic particle and dye penetrant testing.

Thickness and hardness

Ultrasonic thickness and hardness at selected locations.

Metallurgical examination

In-situ metallography and material checks.

Tabulated RLA study

Findings assessed on the agreed basis and tabulated.

Report and advice

Continue, repair or replace, with our repair team ready.

Our people

Meet our technical team

Certified specialists in metallurgy, NDE and welding, with 20+ years of experience.

PS
Prem SunarMetallurgist
DL
Digambar LingayatNDE Level I technician
RZ
Rupesh ZendeNDE Level II technician
AS
Atish SankpalNDE Level II technician
KR
Kailas RandiveNDE Level II technician
AD
Akash DeshmukhNDE Level II technician
TA
Tarif AnsariWelding technician
PS
Prithwiraj SawantProject administrator

See the full team

Stay connected

Completed projects, live from LinkedIn

Follow our completed projects on LinkedIn

See our latest project updates, inspections and team news, live from the VTS LinkedIn page, without leaving this website.

Follow on LinkedIn
Vishwakarma Technical ServicesLatest updates from LinkedIn

Our latest project posts appear here. You can also read them on our LinkedIn page.

Open our posts
Questions

Frequently asked questions

Why industrial inspection is required
Boilers and pressure vessels work at high pressure and temperature, so small defects can grow into failures. Inspection finds cracks, wall thinning and weld defects early, supports safe operation and the statutory requirements for the equipment, and helps avoid forced shutdowns.
When should a boiler undergo an RLA?
Common triggers are reaching the design life, long periods at high temperature, repeated tube failures, plans for life extension, or a change in operating conditions. The right timing depends on the boiler, its history and the regulations that apply, so ask an engineer to assess your case.
MT or DPT: which method should I use?
Use magnetic particle testing (MT) on ferromagnetic material such as carbon and low-alloy steel, when you need surface and very shallow subsurface cracks. Use dye penetrant testing (DPT) on clean, non-porous material that is not magnetic, such as austenitic stainless steel, aluminium and titanium, but only for flaws open to the surface. MT does not work on non-magnetic metals, and DPT cannot see a flaw that is closed to the surface. A simple rule: if the material is magnetic, think MT first; if the flaw is open to the surface on any metal, DPT will show it. The governing code and procedure decide the final choice.
Indian Boiler Regulations (IBR)
The Indian Boiler Regulations are statutory regulations for boilers in India. They cover matters such as materials, repairs, welding of pressure parts and certification of welders. Compliance is a legal requirement, and the inspecting authority decides on acceptance.
What is boiler RLA and when is it needed?
Boiler RLA (remaining life assessment) estimates how much safe service life is left in boiler pressure parts such as tubes, headers and drums. It combines inspection data, thickness measurements, metallurgical examination and the operating history of the boiler. It is usually considered when a boiler approaches its design life, has run for long periods at high temperature, has repeated tube failures, or when the owner plans life extension. The scope depends on the boiler and the regulations that apply, so ask an engineer to define it for your plant.
How often should an industrial boiler be inspected?
Boilers in India must be inspected and certified as the Indian Boiler Regulations require, and the inspecting authority decides the schedule for the certificate. Many plants also plan their own inspection at each shutdown, covering tubes, headers, drums, welds and wall thickness, and add NDT where the boiler history shows wall loss or cracking. The right interval depends on the age, pressure, fuel, water quality and failure history of the boiler, so ask an engineer to plan it for your boiler.

Visit the Knowledge Centre

ISO 9001:2015Certified quality management
On-time complianceESIC, PF and MLWF awards
Safety firstPPE and LOTO kits in use
60+ page reportsDetailed documentation per project
IBR-certified weldersFor boiler pressure parts

Planning a shutdown or facing a breakdown?

We know your urgency. Tell us the problem and we will plan the right testing.

Send an enquiry
Send enquiry